Vibration Data Processing Workflow

How to process accelerometer and vibration test data — FFT, PSD, frequency response, windowing and sampling considerations.

Article 11.02Test & Data Tools4 min read
vibrationaccelerometerFFTPSDsignal processingtest data

Engineering Task

Processing vibration test data to extract frequency content, PSD or frequency response functions for correlation with FE models.

Workflow

  1. Verify sampling rate — must be at least 2.5× the highest frequency of interest (Nyquist)
  2. Apply windowing (Hanning) to reduce spectral leakage in FFT
  3. Compute FFT or PSD using Welch averaging for statistical reliability
  4. For FRF: compute output/input cross-spectrum and input auto-spectrum
  5. Check coherence — low coherence indicates noise, leakage or nonlinearity

Key Considerations

  • Sampling rate: at least 2.5× (practically 5×) the highest frequency of interest
  • Windowing: Hanning for general use; flattop for amplitude accuracy
  • Averaging: use at least 8–16 averages for stable PSD or FRF estimates
  • Units: verify g²/Hz for PSD, g/N for FRF — unit errors are common
  • Sensor calibration: apply sensitivity (mV/g) from the calibration certificate