Delamination Analysis Checklist
A checklist for delamination analysis — method selection, parameters, interfaces and verification.
Checklist
- Delamination-prone interfaces identified (free edges, ply drops, joints)
- Method selected: cohesive zones (initiation+propagation) or VCCT (propagation)
- Interface strengths from test data
- G_Ic and G_IIc from DCB and ENF tests
- Mixed-mode criterion specified (power law or B-K)
- Mesh adequate for process zone (cohesive) or crack front (VCCT)
- Verification with DCB/ENF simulation completed
- Mesh sensitivity checked